Inverter/Charger Installation
975-0639-01-01 Rev A 1–29
This guide for use by qualified personnel only
Figure 1-14 Conext SW BTS and Xanbus Connections
Battery
Negative
Battery
Positive
Xanbus Stacking REM BTS
/
(1) Install the BTS sensor on the battery.
Method
(a) involves mounting the sensor to the
negative battery post which allows the internal
battery temperature to be sensed providing the
most accurate results.
Method (b) attaches the sensor to the side of
the battery using the self-adhesive backing
which also provides good results in most
situations.
(2) Plug the BTS connector to the BTS port of
the inverter/charger.
(2)
(1)(a)
(1)(b)
(3)
(c)
BTS
battery cable
battery terminal
(3) Connect the Xanbus-enabled devices
using the provided network cable. Terminate
each end of the network with a network
terminator
(c) and (d).
(d)
ConextSW-NA-InstallationGuide.book Page 29 Thursday, December 20, 2012 2:05 PM