Time Relays
Standards
IEC 60669-2-3
Pulsar T
Function
Conditioning of incoming source to exact predictable output.
Applications
From the delayed lighting of driveways (to avoid unneccessary on/off
switching), to after-circulation of a pump (to build in some hysteresis,
again to avoid continuous on/off switching) to the post-present
ventilation of a meeting room.
Features
Devices with delay on (ON), delay off (OFF), combined on-off-delay
(ON/OFF)
,
astable (AS), positive edge single shot (PS) negative edge single shot (NS) and
even with all the above combined in one multi-function (MF) device are available.
User presettable prescaler and time.
In the case of the multi-function relay, the function itself is also user selectable.
The loss-proof safety terminals are equipped with Pozidriv screws and have
IP20 protection degree.
Performance
PLT + AS Other PLT +
Rated current (acc. IEC 669-2-3)
A 1 (static) 16
Width (number of DIN-modules)
11
Contacts
Changeover - 1
Static input 1 -
Time range
1 function 0.1s./ 60s. 1s / 60mn
Multifunction no 0.1s. / 20h.
Supply voltage
230/240V - 50/60 Hz yes yes
24VAC/24VDC yes yes
Supply voltage range (in % of Un) % 90-110 90-110
Rated power consumption
Closed circuit current 230V VA 4.0 1.5
24V VA - 0.2
Working current(ignition & running) 230V VA 4.0 4.0
24V VA - 2.0
Light types
Incandescent lamps yes yes
Fluorescent lamps yes yes
Switching capacity
AC-5b Incandescent lamps (40 to 200 W lamps) W 2,300 2,300
Fluorescence compensated (cos
ϕ
=0.9)
Serial compensation W - 2,300
Parallel compensation VA - 1,000
Inductive load cos
ϕ
=0.5
230W 10A
Load AC-7b W - 900
Lifetime (in number of operations)
(1)
Electrical (AC-1) at 1,200 W 2 x 10
6
2 x 10
6
at full load 1 x 10
6
3 x 10
5
Mechanical 1 x 10
7
1 x 10
7
General specifi cations
DIN rail mounting yes yes
Silent operations yes yes
Setting accuracy - Full range % +/- 15 +/- 15
Continuously adjustable time-lag yes yes
Front switch-off lever yes no
Clamping screw terminals, unlosable screws yes yes
Cable cross section (Ø min/max) Coil mm² 1.5 / 10 1.5 / 10
Load mm² 1.5 / 10 1.5 / 10
Maximum torque on terminals N x m 1 1
Ambient temperature at installation point (min./max.) °C -20 / +45 -20 / +45
(1) cycle = 2 operations per pole (closing + opening)